Polarimeter

Polarimeters from A.KRÜSS are ideal for analyzing optically active substances by determining their angle of rotation. They support all applications in industry, research, development and training.

A.KRÜSS P8000-P and P8100-P Polarimeters

High-Speed Polarimetry with Precise Peltier Temperature Control

The A.KRÜSS P8000-P and P8100-P Polarimeters are cutting-edge instruments designed for rapid and accurate analysis of optically active substances. Equipped with advanced Peltier temperature control, these models ensure precise thermal regulation directly at the sample, eliminating the need for external temperature control devices. This feature makes them ideal for applications in the pharmaceutical, chemical, food, and beverage industries, where stringent temperature control is essential.


Key Features:

  • Rapid Measurement: Achieve measurement times of approximately 1 second, significantly enhancing laboratory throughput.

  • Peltier Temperature Control: Integrated Peltier elements provide accurate, homogeneous, and fast temperature regulation directly at the sample tube, ensuring precise measurements without external devices.

  • High Accuracy: The P8000-P offers a measurement accuracy of ±0.003°, while the P8100-P provides an enhanced accuracy of ±0.002°, catering to applications requiring high precision.

  • User-Friendly Interface: Features a 7.0-inch capacitive touchscreen for intuitive operation, allowing easy access to various measurement modes and settings.

  • Versatile Measurement Scales: Pre-installed scales include optical rotation (°), specific rotation, international sugar scale (°Z), and concentration (g/100 ml), with the option to set up additional user-defined scales.

  • Compliance with Industry Standards: Conforms to GMP/GLP, 21 CFR Part 11, and various pharmacopoeias, ensuring suitability for regulated environments.


Technical Specifications:

Specification

P8000-P

P8100-P

Measurement Range ±90°; ±259 °Z ±90°; ±259 °Z
Measurement Accuracy ±0.003°; ±0.01 °Z ±0.002°; ±0.01 °Z
Resolution 0.001°; 0.01 °Z 0.001°; 0.01 °Z
Measurement Period Approximately 1 second Approximately 1 second
Light Source 1 LED with filter 1 LED with filter
Wavelength 589 nm 589 nm
Temperature Control Range 15–40 °C 15–40 °C
Temperature Control Accuracy ±0.2 °C ±0.2 °C
Temperature Measurement Accuracy ±0.1 °C ±0.1 °C
Display 7.0-inch capacitive touchscreen 7.0-inch capacitive touchscreen
Interfaces USB, RS-232, Ethernet, LIMS USB, RS-232, Ethernet, LIMS
Dimensions (W × H × D) 670 mm × 200 mm × 360 mm 670 mm × 200 mm × 360 mm
Weight 29 kg 29 kg

Applications:

These polarimeters are suitable for various industries, including:

  • Pharmaceuticals: Determining the purity and concentration of active pharmaceutical ingredients.

  • Chemicals: Analyzing chiral compounds and monitoring chemical processes.

  • Food and Beverages: Measuring sugar content and quality control in production processes.

  • Research and Development: Studying optically active substances in academic and industrial research settings.


Conclusion:

The A.KRÜSS P8000-P and P8100-P Polarimeters offer unparalleled speed and precision in polarimetric analysis. Their advanced Peltier temperature control system ensures accurate and reliable measurements, making them indispensable tools for laboratories demanding high performance and compliance with industry standards.

A.KRÜSS P8000-T and P8100-T Polarimeters

High-Precision Polarimetry with Water-Bath Temperature Control

The A.KRÜSS P8000-T and P8100-T Polarimeters are designed for precise analysis of optically active substances, featuring water-bath temperature control for accurate and homogeneous sample temperature regulation. These instruments are ideal for applications in the pharmaceutical, chemical, food, and beverage industries, where maintaining specific sample temperatures is crucial for reliable measurements.


Key Features:

  • Water-Bath Temperature Control: Utilizes an external circulation thermostat to maintain sample temperatures between 8 °C and 35 °C, ensuring precise thermal conditions during measurements.

  • Rapid Measurement: Achieves measurement times of approximately 1 second, significantly enhancing laboratory throughput.

  • High Accuracy: The P8000-T offers a measurement accuracy of ±0.003°, while the P8100-T provides an enhanced accuracy of ±0.002°, catering to applications requiring high precision.

  • User-Friendly Interface: Features a 7.0-inch capacitive touchscreen for intuitive operation, allowing easy access to various measurement modes and settings.

  • Versatile Measurement Scales: Pre-installed scales include optical rotation (°), specific rotation, international sugar scale (°Z), and concentration (g/100 ml), with the option to set up additional user-defined scales.

  • Compliance with Industry Standards: Conforms to GMP/GLP, 21 CFR Part 11, and various pharmacopoeias, ensuring suitability for regulated environments.


Technical Specifications:

Specification

P8000-T

P8100-T

Measurement Range ±90°; ±259 °Z ±90°; ±259 °Z
Measurement Accuracy ±0.003°; ±0.01 °Z ±0.002°; ±0.01 °Z
Resolution 0.001°; 0.01 °Z 0.001°; 0.01 °Z
Measurement Period Approximately 1 second Approximately 1 second
Light Source 1 LED with filter 1 LED with filter
Wavelength 589 nm 589 nm
Temperature Control Range 8–35 °C 8–35 °C
Temperature Control Accuracy ±0.2 °C ±0.2 °C
Temperature Measurement Accuracy ±0.1 °C ±0.1 °C
Display 7.0-inch capacitive touchscreen 7.0-inch capacitive touchscreen
Interfaces USB, RS-232, Ethernet, LIMS USB, RS-232, Ethernet, LIMS
Dimensions (W × H × D) 670 mm × 200 mm × 360 mm 670 mm × 200 mm × 360 mm
Weight 29 kg 29 kg

Applications:

These polarimeters are suitable for various industries, including:

  • Pharmaceuticals: Determining the purity and concentration of active pharmaceutical ingredients.

  • Chemicals: Analyzing chiral compounds and monitoring chemical processes.

  • Food and Beverages: Measuring sugar content and quality control in production processes.

  • Research and Development: Studying optically active substances in academic and industrial research settings.


Conclusion:

The A.KRÜSS P8000-T and P8100-T Polarimeters offer rapid and precise polarimetric analysis with reliable water-bath temperature control. Their advanced features and compliance with industry standards make them indispensable tools for laboratories demanding high performance and accuracy.

A.KRÜSS P3000 Polarimeter

Economical Solution for Standard Polarimetric Measurements

The A.KRÜSS P3000 Polarimeter offers an affordable and efficient solution for laboratories performing routine analysis of optically active substances. Designed for applications where a measurement accuracy of ±0.01° is sufficient, the P3000 delivers rapid results with a measurement time of approximately 1 to 2 seconds. Its user-friendly 3.5-inch capacitive touchscreen ensures intuitive operation, making it an ideal choice for quality control in various industries.


Key Features:

  • Fast Measurement: Achieves measurement times of approximately 1 to 2 seconds, enhancing laboratory efficiency.

  • High Accuracy: Provides a measurement accuracy of ±0.01°, suitable for standard applications.

  • User-Friendly Interface: Equipped with a 3.5-inch capacitive touchscreen for easy and intuitive operation.

  • Versatile Measurement Scales: Displays results as optical rotation (°) or in the International Sugar Scale (°Z), catering to diverse application needs.

  • Reliable Temperature Compensation: Features dependable temperature compensation, allowing measurements at various temperatures with automatic conversion to the value at 20 °C.

  • Compliance with Industry Standards: Meets requirements of pharmacopoeias [USP, BP, JP, Ph. Eur. (with temperature control)], GLP, ASTM, ICUMSA, and NIST, ensuring suitability for regulated environments.


Technical Specifications:

Specification

P3000

Measurement Range ±90°; ±259 °Z
Measurement Accuracy ±0.01°; ±0.01 °Z
Resolution 0.01°; 0.01 °Z
Measurement Period Approximately 1–2 seconds
Light Source 1 LED with filter
Wavelength 589 nm
Maximum Tube Length 220 mm
Temperature Measurement Accuracy ±0.1 °C
Display 3.5-inch capacitive touchscreen
Interfaces 1× RS-232
Dimensions (W × H × D) 645 mm × 200 mm × 360 mm
Weight 28 kg
Operating Voltage 110–250 V AC
Rated Frequency 50/60 Hz

Applications:

The P3000 Polarimeter is suitable for various industries, including:

  • Pharmaceuticals: Monitoring chemical processes, purity control, and concentration determination.

  • Chemicals: Analyzing optically active components, determining configuration changes, and monitoring chemical processes.

  • Food and Beverages: Determining concentrations, purity control, and quality assurance.

  • Sugar and Sweetener Industry: Quality control of raw materials and end products, including the determination of fructose and glucose levels.


Conclusion:

The A.KRÜSS P3000 Polarimeter provides a cost-effective and reliable solution for standard polarimetric measurements. Its rapid measurement capability, user-friendly interface, and compliance with industry standards make it an excellent choice for laboratories focused on routine analysis and quality control.

A.KRÜSS P1000-LED Manual Polarimeter

Reliable and Economical Solution for Basic Laboratory Applications

The A.KRÜSS P1000-LED Manual Polarimeter is a robust and user-friendly instrument designed for fundamental laboratory applications and educational purposes. It operates on the half-shade principle, allowing for precise measurement of optical rotation in various substances. This polarimeter is ideal for industries such as pharmaceuticals, food and beverage, and academia.


Key Features:

  • Durable Construction: Built with a high-quality metal stand, ensuring long-lasting performance in laboratory environments.

  • Efficient LED Illumination: Equipped with a high-performance LED light source with a wavelength of 589 nm, offering a service life up to 2000 times longer than conventional sodium discharge lamps, resulting in minimal maintenance.

  • Versatile Sample Accommodation: Features a sample chamber that accommodates measurement tubes up to 220 mm in length, providing flexibility for various sample sizes.

  • Precise Measurement: Utilizes the half-shade principle, with measurement results read through an eyepiece and two noniuses, achieving a readability of 0.05°.

  • Comprehensive Accessories: Includes two measurement tubes (100 mm and 200 mm) with a debubbler for proper filling, facilitating immediate use upon setup.


Technical Specifications:

Specification

P1000-LED

Measurement Range 2×180° (two graduated circles)
Scale Graduation
Readability 0.05° (with nonius)
Light Source 1 LED with filter
Wavelength 589 nm
Sample Chamber Length Up to 220 mm
Dimensions (W × H × D) 140 mm × 340 mm × 440 mm
Weight 5 kg
Power Supply 110–250 V, 50/60 Hz

Applications:

  • Pharmaceuticals: Ideal for incoming and outgoing goods inspection, as well as quality control of pharmaceutical products in accordance with pharmacopoeias.

  • Education and Training: Widely used in academic settings for practical exercises and experiments, such as studying the kinetics of cane sugar inversion and the mutarotation of glucose.

  • Food and Beverage Industry: Suitable for analyzing sugar solutions and other optically active substances, ensuring product quality and consistency.


Conclusion:

The A.KRÜSS P1000-LED Manual Polarimeter offers a reliable and cost-effective solution for basic polarimetric measurements. Its durable construction, efficient LED illumination, and precise measurement capabilities make it an excellent choice for laboratories and educational institutions seeking dependable performance in routine applications.

©2025 Built with love by REYELISE Ltd.

CONTACT US

We're not around right now. But you can send us an email and we'll get back to you, asap.

Sending

Log in with your credentials

Forgot your details?