Claire® lh
Integrated Automated Liquid Handling and Class II Laboratory Protection
Automate your pipetting. Protect your personnel and samples. Bring both together in one integrated system.
The Berner claire® lh combines BRAND’s Liquid Handling Station with a Berner Class II safety cabinet to create a coordinated solution for automated sample processing.
Developed jointly by BRAND and Berner, this system brings together flexible liquid handling, intuitive method control and tested personnel, product and carry-over protection. It supports the processing of toxic and non-toxic samples under GMP Grade A conditions, combining automation with a protective laboratory environment.
From routine liquid transfers to changing pipetting workflows, claire® lh provides an adaptable platform designed around your process.
An Integrated System with Tested Protection
Placing a pipetting robot inside a safety cabinet is not enough on its own: the combined arrangement must maintain the required protective performance.
The claire® lh integrates BRAND’s Liquid Handling Station into the cabinet’s working plane. Its geometry and positioning are designed to support personnel and product protection during automated operation.
The combined system fulfils the requirements for personnel, product and carry-over protection according to DIN EN 12469, as stated in its CE declaration of conformity.
The system is based on the B-2-130 model size of Berner’s claire® pure series, with modifications specifically designed for the integrated Liquid Handling Station.
Flexible Liquid Handling for Changing Tasks
BRAND’s Liquid Handling Station provides a versatile platform for different sample formats and pipetting methods.
Seven freely assignable workstations in ANSI/SLAS format accommodate combinations of:
- Single tubes.
- Eight-well PCR tube strips.
- Reservoirs.
- 96-well plates.
- 384-well plates.
For contact-free liquid dispensing, single-channel and eight-channel liquid ends are available.
Application-specific accessories include:
- Shaking and temperature-control modules.
- Cooling blocks.
- Additional accessories for different liquid-handling workflows.
The manufacturer’s general application overview also describes configurations with up to eight workstations. The detailed Liquid Handling Station description specifies seven freely assignable ANSI/SLAS-format positions; the required deck configuration should therefore be confirmed when selecting the system.
Position the Automation Where Your Process Needs It
The Liquid Handling Station can be positioned to the left, right or centre of the cabinet workspace.
This flexibility allows the working area to be arranged around the task, the equipment and the operator’s access requirements.
Rather than imposing one fixed layout, claire® lh allows the integrated automation to be positioned to suit the intended workflow.
Automated Methods Without Programming Knowledge
A connected laptop or PC controls the Liquid Handling Station through its dedicated software.
No programming knowledge is required to define methods and run the specified processes automatically. The software provides information about each method step, automatically logs processes and checks them for inconsistencies.
This approach supports repeatable automated workflows while reducing the manual work involved in pipetting.
Berner reports a 70% time saving compared with manual pipetting. Actual time savings depend on the method and workflow.
A laptop or PC must be supplied separately by the user and is not included in the delivery scope.
Controlled Access During Pipetting
An intelligent locking mechanism supports operator safety during automated processing.
After the Liquid Handling Station has been loaded and the system switches to pipetting mode, the front window closes sufficiently to prevent unintended reaching into the workspace.
This arrangement restricts access during the automated pipetting process while bringing the cabinet and Liquid Handling Station into a coordinated operating mode.
Two Uses in One System
The Liquid Handling Station is easily removable, allowing the cabinet to support work beyond automated pipetting.
With the optional standard worktop configuration, claire® lh can be used as a Class II microbiological safety cabinet for other laboratory activities.
This dual-use concept provides flexibility for laboratories that need both automated liquid handling and a cabinet for additional laboratory work.
Clear Control through a High-End Touch Display
The integrated touch display provides quick, straightforward control of the safety cabinet and the Liquid
Handling Station’s operating modes.
Both systems are brought together in a clearly presented interface, with the safety status immediately visible to the operator.
The touchscreen coordinates cabinet operation and system modes, while the connected computer runs the liquid-handling methods.
Ergonomics for Everyday Laboratory Work
claire® lh combines bright, particularly quiet working conditions with adjustable working height and comfortable legroom.
The supplied base frame offers seven adjustment steps between 683 and 952 mm.
A compact first main filter stage helps preserve legroom beneath the working area. An electric lifting underframe is available as an option for laboratories requiring additional height-adjustment functionality.
Included Equipment
The claire® lh system combines the BRAND Liquid Handling Station with the modified Berner safety cabinet.
The published delivery scope includes:
- Modified three-part worktop set.
- Connections for supplying power to the Liquid Handling Station and connecting it to the cabinet control unit.
- Left-side USB interface for connecting the user’s PC or notebook.
- Liquid Handling Station software and basic equipment.
- Ergonomically adjustable base frame with seven settings between 683 and 952 mm.
- Filter test connections.
- Functional socket within the working area.
- Preparation for additional sockets or interfaces.
- UV-C disinfection system.
Optional equipment and accessories include:
- Electric lifting underframe.
- Standard worktop configuration for use without the Liquid Handling Station.
- Shaking and temperature-control modules.
- Cooling blocks.
- Additional liquid-handling accessories.
The precise accessory package should be selected to match the intended application.

German Manufacturing and Lifecycle Support
Both the safety cabinet and the Liquid Handling Station are manufactured in Germany. A high proportion of German suppliers supports short supply chains, with assembly and technical testing performed directly by the manufacturer.
Berner Service supports the integrated system throughout its lifecycle, including:
- Commissioning.
- Annual maintenance.
- Technical support for the safety cabinet and Liquid Handling Station.
Bring Automation and Protection into One Workflow
With claire® lh, automated liquid handling becomes part of a tested Class II protective system—not a separate instrument placed inside a cabinet.
Configure the labware, liquid ends, accessories and workspace arrangement around your methods, while retaining the flexibility to use the cabinet for other laboratory tasks.